Using compressed air or steam, Hurricane air blowers provide high volumes of air with NO MOVING PARTS. Hurricane blowers are used in supplying or exhausting applications such as: tanks, towers, refineries, process plants, pressure vessels, cooling/drying applications, foundries, sand blasting and shipyard applications, manholes, cargo holes, and other similar confined work areas. Hurricanes are also suited for use in hazardous atmospheric locations.

Venturi Air Blowers - Principle of Operation

In the Hurricane, air or steam enters a concentric manifold chamber surrounding a Venturi throat. A series of orifices located symmetrically around the chamber are positioned to expand the air or steam into the reaction zone downstream of the throat. It is here that the high velocity air or steam imparts its energy to slower moving air and accelerates it, which in turn draws more air through the throat into the reaction zone. A conical-shaped diffuser controls direction and expansion of the accelerated air.

 

Technical Data:

Supply Pressure (psig) Static Pressure (in wg)
Model 0.0" 0.5" 1.0" 1.5" 2.0"
40 3P 970 900 830 720 620
3 1080 1000 920 800 690
6 2750 2500 1900 950 750
8 4030 3520 2600 1950 920
9 5830 5100 4300 3600 2800
10 6200 5400 5000 4400 3400
60 3P 1125 1070 1000 936 840
3 1250 1190 1120 1040 930
6 3450 3225 2900 2300 1100
8 5000 4700 4100 3550 2700
9 6840 6400 6050 5200 4800
10 7500 6800 6400 6000 5000
80 3P 1350 1285 1190 1100 1000
3 1500 1425 1325 1225 1120
6 4000 3775 3500 3400 2775
8 6000 5600 5050 4600 6000
9 8000 7500 7000 6400 6000
10 8500 8000 7600 7000 6600
100 3P 1575 1520 1450 1375 1290
3 1750 1680 1610 1525 1430
6 4600 4425 4225 3975 3700
8 6300 5730 5290 4920 3990
9 8900 8300 7700 7000 6600
10 10500 9500 8000 7500 6800

 

Air Flow Through Flexible Duct

 

Supply Pressure (psig) Duct Length (ft)
Model 10' 20' 30' 40' 50'
80 3P 1300 1260 1215 1170 1150
3 1450 1400 1350 1300 1275
6 3800 3600 3425 3300 3210
8 5700 5350 5000 4700 4200
9 7350 6900 6500 6300 5200
10 8000 7600 7000 6600 5600

 

Air Consumption (SCFM)

 

Supply Pressure (psig) Static Pressure (in wg)
Model 0.0" 0.5" 1.0" 1.5" 2.0"
40 3P 32 30 27 24 20
3 34 32 29 25 22
6 66 60 46 23 18
8 116 101 75 56 27
9 201 176 149 125 97
10 194 169 157 138 107
60 3P 45 43 40 38 34
3 49 46 44 40 36
6 96 90 81 64 31
8 167 157 137 119 90
9 274 256 242 208 192
10 268 243 229 215 179
80 3P 57 54 50 46 42
3 60 57 53 49 45
6 160 151 140 136 111
8 231 216 195 177 150
9 381 358 334 305 285
10 405 381 362 334 315
100 3P 72 70 66 63 59
3 77 74 70 67 63
6 220 211 202 190 177
8 315 287 265 246 200
9 445 415 385 350 330
10 584 528 445 416 378

 

 

Dimensions and Weights:

 

  

 Model A B C Air Inlet Mounting Flange Weight
D E # of Notches Width of Notch
3P 8" 6" 17" 1/2" 7.25 4 0.63 7
3 8" 8" 36" 1/2" 7.25 4 0.63 9
6 11.5" 12" 45" 1" 10.75 4 0.63 26
8 14.5" 14" 48" 1" 13.5 4 0.63 38
9 16.8" 14" 48" 1" NPT 15.3 10 0.937 42
10 17.5" 15.75" 48" 1" 15.5 4 0.63 42


Questions? Comments? Contact us at sales@airtools.com